Digital Display Controller – D1100

Industrial digital display controller for process monitoring and control.
The D1100 features a clear four-digit LED display for temperature, pressure, level, and speed signals. Suitable for automation, laboratory, packaging, and water/wastewater systems, it supports multiple signal inputs, programmable settings, and RS485 communication for easy integration with sensors and VFDs.

Applications

  • Industrial temperature, pressure, and level control

  • Pump and fan monitoring in VFD-based systems

  • Laboratory and quality control measurement

  • Packaging and food processing automation

  • HVAC and building automation monitoring

Description

The D1100 Digital Display Controller is a single-loop industrial display controller designed for precise monitoring and control of process signals in a wide range of applications, including temperature control, pressure monitoring, liquid level measurement, speed control, laboratory equipment, packaging machinery, and industrial automation systems.

Equipped with a double four-digit LED display, the D1100 provides real-time visualization of process values. Its modular design ensures simple installation, intuitive operation, and reliable performance. The controller is compatible with voltage, current, thermocouples, and thermal resistor inputs, allowing seamless integration with various industrial sensors.

With RS485 communication support, the D1100 can transmit process signals to PLC, SCADA, or VFD-based systems, making it an ideal choice for pump, fan, and HVAC control loops. Its user-friendly interface, high accuracy (±0.3% FS), and programmable settings ensure consistent process stability and operational efficiency.

Integration & Compatibility:
The D1100 is designed to work seamlessly with industrial sensors (pressure, flow, level, temperature) and can be used alongside VFDs, pumps, fans, and PLC/SCADA systems. This makes it ideal for process automation, water/wastewater, HVAC, and building automation systems.


Application-Specific Engineering Recommendations

LONGVISTA provides practical engineering guidance to ensure that digital displays, controllers, and data recorders deliver optimal performance in your system. Our recommendations focus on signal compatibility, VFD integration, and process-specific control logic.


1️⃣ HVAC Systems

  • Use Case: AHUs, fan coil units, ventilation, CO₂ or temperature control

  • Recommendation:

    • Connect temperature, humidity, or CO₂ sensors to the display/controller.

    • Configure alarm thresholds for comfort and air quality compliance.

    • Use RS485/MODBUS communication for integration with VFD-driven fans.

  • Outcome: Stable indoor climate, energy-efficient operation, and simplified BMS integration.


2️⃣ Water & Wastewater Systems

  • Use Case: Pump stations, water treatment, level and pressure monitoring

  • Recommendation:

    • Connect pressure, level, or flow sensors to controllers.

    • Use display outputs for real-time monitoring at control panels.

    • Feed analog or digital outputs to VFDs or PLCs for automated pump speed adjustment.

  • Outcome: Reduced energy consumption, smoother pump operation, and improved process reliability.


3️⃣ Industrial Process Automation

  • Use Case: Temperature, pressure, or speed control in manufacturing lines

  • Recommendation:

    • Use single-loop controllers or multi-channel recorders for accurate process visualization.

    • Configure alarms, data logging, and analog outputs for real-time feedback and quality control.

  • Outcome: Consistent product quality, minimal downtime, and streamlined process management.


4️⃣ General Engineering Best Practices

  • Ensure sensor type and signal range match the input configuration of the controller.

  • Verify power supply compatibility (AC/DC options).

  • Use shielded cables for analog signals to reduce interference.

  • Calibrate devices regularly to maintain accuracy within ±0.3% F.S.

  • For VFD-driven systems, configure feedback loops carefully to avoid over/under-speed conditions.


Features

  • Double four-digit LED display for real-time process monitoring

  • Supports 33 fully switchable signal inputs

  • Input deviation correction and small signal resection

  • High measurement accuracy ±0.3% FS, resolution 0.1°C

  • Modular design for easy installation and operation

  • Measurement, alarm, transmission, communication, and power distribution functions

  • RS485 communication output for integration with PLC, SCADA, and VFD systems

  • Compatible with voltage, current, thermocouples, and thermal resistor inputs

  • Feed output: DC24V ±1V, ≤30 mA (load resistance ≥750Ω)

  • Operating temperature: -10℃~50℃ (no condensation, no freezing)


Specification

Parameter Specification
Accuracy ±0.3% F.S
Display Range -1999 ~ 9999
Input Signal Voltage, current, thermocouple, thermal resistor (RTD)
Output 4–20 mA, 1–5V, 0–10 mA, 0–5V, 0–20 mA, 0–10V
Communication Output RS485
Feed Output DC24V ±1V, ≤30 mA (load resistance ≥750Ω)
Power Supply AC/DC 100–240V, 50/60Hz ≤5W; DC12–36V ≤3W
Operating Temperature -10℃~50℃ (no condensation, no freezing)

 

FAQ

1️⃣ What is the D1100 Digital Display Controller used for?

The D1100 is an industrial single-loop LED display controller designed to monitor and control process signals such as temperature, pressure, liquid level, and speed. It is commonly used in HVAC, water/wastewater systems, industrial automation, packaging machinery, and laboratories.


2️⃣ Which sensors can be connected to the D1100?

The D1100 supports multiple industrial signals, including:

  • Voltage and current signals (e.g., 4–20 mA, 0–10 V)

  • RTDs (PT100 / PT1000) for temperature

  • Thermocouples for high-accuracy temperature measurement

This makes it compatible with pressure, flow, level, and temperature sensors, including MACSENSOR and Paku devices.


3️⃣ Can the D1100 work with VFDs?

Yes. The D1100 can provide real-time measurement signals and alarms to Variable Frequency Drives (VFDs) for pumps, fans, and HVAC systems. By using the D1100 in your control loop, you can optimize energy efficiency, system stability, and process control.


4️⃣ What communication options are available?

The controller features RS485 communication (MODBUS RTU), allowing remote monitoring and integration with PLC, SCADA, or building automation systems. This ensures compatibility in industrial and commercial setups.


5️⃣ What is the operating environment of the D1100?

  • Temperature range: -10°C to 50°C (no condensation or freezing)

  • Power supply options: AC/DC 100–240V or DC 12–36V

  • Feed output: DC24V ±1V, ≤30 mA (load resistance ≥750Ω)

It is designed for robust industrial environments without the need for special enclosures.


6️⃣ How accurate is the D1100?

The D1100 offers high-precision measurements with:

  • ±0.3% F.S accuracy

  • Resolution: 0.1°C

  • Input deviation correction and small signal filtering

This ensures stable and reliable readings for critical processes.


7️⃣ Can I integrate multiple sensors or signals?

Yes. The D1100 supports up to 33 fully switchable signal inputs. Measurement, alarm, transmission, communication, and power distribution functions form a complete digital acquisition and control system.


8️⃣ Who should use the D1100?

The D1100 is ideal for:

  • Automation engineers and system integrators in HVAC, water/wastewater, and industrial processes

  • Maintenance teams requiring local process monitoring

  • Laboratories and R&D teams needing precise signal display and control

  • Businesses implementing VFD-driven pumps or fans


Datasheet

Digital Display Controller – D1100 – Datasheet