[wpseo_breadcrumb]
Variable Frequency Drive 400V:
Top Performance Without Compromises
3 Phase 400V VFDs with standard Features
✔ Motor Rated Power: 1.5 kW to 110 kW
✔ Compact Design
✔ U/f & Sensorless Vector Control
✔ Certified STO Function (SIL2/SIL3)
✔ Integrated C3 Filters (≥ 4 kW)
✔ Integrated DC Reactor from 18.5 kW to 110 kW
✔ ‘Side-by-Side’ DIN Rail Mounting ≤ 2.2 kW
✔ Integrated Brake Chopper
✔ Overload Capacity: 150% / 60 Sec.
✔ Modbus RTU & ASCII
✔ IP20 Protection Rating
3 Phase 400V VFDs with Advanced Features
✔ Motor Rated Power: 1.5 kW – 500 kW
✔ SVC and Closed-Loop Vector Control (VC)
✔ Dual Rating (Normal Duty + Heavy Duty)
✔ Precise Speed, Torque, and Position Control
✔ STO Function
✔ Integrated C3 Filters
✔ Integrated Brake Chopper up to 45 kW
✔ Modbus RTU® on board as standard
✔ 3 Expansion Slots for Optional PLC Cards, I/O Cards, Communication Cards, Feedback Cards
✔ Standard USB interface
✔ IoT Functionality
✔ Multifunctional LCD Keypad
✔ Supports Ethernet/IP, Profinet, CAN Master/Slave, and more.
✔ Fire Mode
✔ IP20 Protection Rating, IP55 optional
3 Phase 400V VFDs with standard Features
Built-in C3 Filter
Built-In DC Reactor from 18.5 kW
Common DC Bus Solution
External Keypad
Flange Mounting Plate or Pass-Through Variant
3 Phase 400V VFDs with Advanced Features
Multifunction LCD Control Panel
Internet of Things (IoT) Connectivity
Support for Various Industrial Communication Protocols
Optional PLC, I/O, Communication, and PG Cards
Technical Specifications for 3 Phase 400V VFDs with standard Features
400V VFD | 1R5G4-EU | 2R2G4-EU | 004G4-EU | 5R5G4-EU | 7R5G4-EU | 011G4-EU | 015G4-EU | 018G4-EU | 022G4-EU | 030G4-EU | 037G4-EU | 045G4-B-EU | 055G4-B-EU | 75G4-B-EU | 090G4-B-EU | 110G4-B-EU |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor Rated Power (kW) | 1,5 | 2,2 | 4 | 5,5 | 7,5 | 11 | 15 | 18,5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 |
Rated Current (A) | 4,2 | 5,5 | 9,5 | 14 | 18,5 | 25 | 32 | 38 | 45 | 60 | 75 | 92 | 115 | 150 | 180 | 215 |
Line Voltage, Frequency | AC 3-ph. 380 V … 440 V (-15% … +10%), 50 Hz/60 Hz (± 5%) | |||||||||||||||
Output Voltage | 3-ph. 0 V … 480 V (max. input voltage) | |||||||||||||||
Overload Capacity | 150% for 60s, 180% for 10s; 200% for 1s | |||||||||||||||
Output Frequency | 0 … 400 Hz | |||||||||||||||
Control Inputs | Analog: 2 Inputs (AI2: 0 … 10 V / 0(4) … 20 mA; AI3: -10 … 10 V) | |||||||||||||||
Digital: 5 programmable inputs, including 1 High-Speed Input (50 kHz) | ||||||||||||||||
Control Outputs | Analog: Up to 2.2 kW 1 Output 0 … 10V / 0 (4) … 20 mA. From 4 kW, 2 Outputs each 0 … 10V / 0 (4) … 20 mA | |||||||||||||||
Digital: 1 potential-free digital output | ||||||||||||||||
2 freely programmable relays with changeover contacts for ≥ 4 kW, 1 freely programmable relay with changeover contact for devices ≤ 2.2 kW | ||||||||||||||||
Interfaces | RS485 on terminals (Modbus RTU & ASCII) | |||||||||||||||
Brake Chopper | Integrated | |||||||||||||||
EMC Filter | Integrated filters (≥ 4 kW); optional filters ≤ 2.2 kW (comply with IEC61800-3 C2, IEC61800-3 C3 requirements) | |||||||||||||||
DC Reactor | – | Integrated | ||||||||||||||
Safety Functions | 2-channel STO, SIL2, PL “d” | 2-channel STO, SIL3, PL “e” | ||||||||||||||
Protection Rating | IP20 | |||||||||||||||
Operating Temperature | -10°C … +50°C; performance reduction required if ambient temperature exceeds +40°C, fan cooling | |||||||||||||||
Certifications | CE, TÜV SÜD, UL, and cUL certification for models 1-ph./3-ph. 220 V ≤ 2.2 kW and 3-ph. 380 V ≤ 11 kW |
TECHNICAL SPECIFICATIONS For 3 Phase 400V VFDs with Advanced Features
High-performance 400V | 1R5G / 2R2P-4 | R2G / 003P-4 | 004G / 5R5P-4 | 5R5G / 7R5P-4 | 7R5G / 011P-4 | 011G / 015P-4 | 015G / 018P-4 | 018G / 022P-4 | 22G / 030P-4 | 030G / 037P-4 | 037G / 045P-4 | 045G / 055P-4 | 55G / 075P-4 | 075G / 090P-4 | 90G / 110P-4 | 110G / 132P-4 | 132G / 160P-4 | 160G / 185P-4 | 185G / 200P-4 | 200G / 220P-4 | 220G / 250P-4 | 250G / 280P-4 | 280G / 315P-4 | 315G / 355P-4 | 355G / 400P-4 | 400G / 450P-4 | 450G / 500P-4 | 500G-4 | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P (ND) | Motor Rated Power | kW | 2,2 | 3 | 5,5 | 7,5 | 11 | 15 | 18,5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | |
Rated Current | A | 5 | 7 | 12 | 17 | 23 | 32 | 38 | 45 | 60 | 75 | 92 | 115 | 150 | 170 | 215 | 260 | 305 | 340 | 380 | 425 | 480 | 530 | 600 | 650 | 720 | 820 | 860 | ||
G (HD) | Motor Rated Power | kW | 1,5 | 2 | 4 | 5,5 | 7,5 | 11 | 15 | 18,5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 |
Rated Current | A | 3,7 | 5 | 9,5 | 14 | 18,5 | 25 | 32 | 38 | 45 | 60 | 75 | 92 | 115 | 150 | 180 | 215 | 260 | 305 | 340 | 380 | 425 | 480 | 530 | 600 | 650 | 720 | 820 | 860 | |
Line Voltage, Frequency | AC 3-ph. 380 V … 440 V (-15% … +10%), 50 Hz/60 Hz (± 5%) | |||||||||||||||||||||||||||||
Output Voltage | 3-ph. 0 V … 480 V (max. input voltage) | |||||||||||||||||||||||||||||
Overload Capacity | 150% for 60s in G setting (Heavy Duty), 120% for 60s in P setting (Normal Duty) | |||||||||||||||||||||||||||||
Output Frequency | 0 … 400 Hz | |||||||||||||||||||||||||||||
Control Inputs Analog | 2 inputs (AI1: 0 … 10 V / 0(4) … 20 mA; AI2: -10 … 10 V), optionally expandable | |||||||||||||||||||||||||||||
Digital: 6 programmable inputs, including 2 high-speed inputs (50 kHz) for speed setpoint or actual value via incremental or pulse encoders, optionally expandable | ||||||||||||||||||||||||||||||
Control Outputs Analog | 1 programmable output 0 … 10 V / 0(4) … 20 mA, optionally expandable | |||||||||||||||||||||||||||||
Digital: 2 programmable outputs, one of them high-speed (50 kHz), potential-free, optionally expandable | ||||||||||||||||||||||||||||||
Relays: 2 programmable changeover contacts (NO/NC), optionally expandable |
||||||||||||||||||||||||||||||
Interfaces | RS485 (terminals) as standard, up to 3 freely configurable option interfaces for communication modules, terminal expansions, feedbacks, and PLC cards | |||||||||||||||||||||||||||||
Brake Chopper | Integrated | Optional | ||||||||||||||||||||||||||||
EMC Filter | Integrated IEC61800-3 C3; IEC61800-3 C1 & C2 optional | |||||||||||||||||||||||||||||
DC Reactor | – | Integrated | Optional | |||||||||||||||||||||||||||
Safety Functions | Two-channel STO (Safe Torque Off) (IEC61800-5-2, SIL2, PL “d”) | |||||||||||||||||||||||||||||
Protection Rating | IP20, optional IP55 | |||||||||||||||||||||||||||||
Ambient Temperature | -10°C … +50°C; power reduction required if ambient temperature exceeds +40°C, air cooling | |||||||||||||||||||||||||||||
Certification | CE, TÜV |
* P = Normal Duty: 120% for 60s G = Heavy Duty: 150% for 60s
Dimensions and Weight
3 Phase 400V VFDs with standard Features
400V VFD | Rated Power (kW) | Dimensions (mm) * Width x Height x Depth | Weight (kg) | ||
---|---|---|---|---|---|
AC 3-ph. 380 V … 440 V (-15% … +10%) | |||||
1R5G-4-EU | 1,5 | 80 | 185 | 140,5 | 1 |
2R2G-4-EU | 2,2 | 80 | 185 | 140,5 | 1 |
004G-4-EU | 4 | 146 | 256 | 167 | 3,1 |
5R5G-4-EU | 5,5 | 146 | 256 | 167 | 3,1 |
7R5G-4-EU | 7,5 | 170 | 320 | 196,3 | 5,6 |
011G-4-EU | 11 | 170 | 320 | 196,3 | 5,6 |
015G-4-EU | 15 | 170 | 320 | 196,3 | 5,6 |
018G-4-EU | 18,5 | 200 | 340,6 | 184,3 | 9 |
022G-4-EU | 22 | 200 | 340,6 | 184,3 | 9 |
030G-4-EU | 30 | 250 | 400 | 202 | 15,5 |
037G-4-EU | 37 | 250 | 400 | 202 | 15,5 |
045G-4-B-EU | 45 | 282 | 560 | 238 | 25 |
055G-4-B-EU | 55 | 282 | 560 | 238 | 25 |
075G-4-B-EU | 75 | 282 | 560 | 238 | 25 |
090G-4-B-EU | 90 | 338 | 554 | 329,2 | 45 |
110G-4-B-EU | 110 | 338 | 554 | 329,2 | 45 |
3 Phase 400V VFDs with Advanced Features
High-performance VFD | Rated Power (kW) at G (HD) / P (ND) | Dimensions (mm) Width x Height x Depth | Weight (kg) | |||
---|---|---|---|---|---|---|
400V Class, 3-Phase | ||||||
1R5G/ 2R2P-4 | 1,5 | 2,5 | 126 | 186 | 185 | 3 |
2R2G/ 003P-4 | 2,2 | 3 | 126 | 186 | 185 | 3 |
004G/ 5R5P-4 | 4 | 5,5 | 126 | 186 | 201 | 3,5 |
5R5G/ 7R5P-4 | 5,5 | 7,5 | 126 | 186 | 201 | 3,5 |
7R5G/ 011P-4 | 7,5 | 11 | 146 | 256 | 192 | 4 |
011G/ 015P-4 | 11 | 15 | 170 | 320 | 220 | 7 |
015G/ 018P-4 | 15 | 18,5 | 170 | 320 | 220 | 7 |
018G/ 022P-4 | 18,5 | 22 | 200 | 340,6 | 208 | 10,5 |
022G/ 030P-4 | 22 | 30 | 200 | 340,6 | 208 | 10,5 |
030G/ 037P-4 | 30 | 37 | 250 | 400 | 223 | 17 |
037G/ 045P-4 | 37 | 45 | 250 | 400 | 223 | 17 |
045G/ 055P-4 | 45 | 55 | 282 | 560 | 256 | 29 |
055G/ 075P-4 | 55 | 75 | 282 | 560 | 256 | 29 |
075G/ 090P-4 | 75 | 90 | 282 | 560 | 256 | 29 |
090G/ 110P-4 | 90 | 110 | 338 | 554 | 330 | 52 |
110G/ 132P-4 | 110 | 132 | 338 | 554 | 330 | 52 |
132G/ 160P-4 | 132 | 160 | 500 | 870 | 360 | 101 |
160G/ 185P-4 | 160 | 185 | 500 | 870 | 360 | 101 |
185G/ 200P-4 | 185 | 200 | 500 | 870 | 360 | 101 |
200G/ 220P-4 | 200 | 220 | 500 | 870 | 360 | 101 |
220G/ 250P-4 | 220 | 250 | 680 | 960 | 380 | 165 |
250G/ 280P-4 | 250 | 280 | 680 | 960 | 380 | 165 |
280G/ 315P-4 | 280 | 315 | 680 | 960 | 380 | 165 |
315G/ 355P-4 | 315 | 355 | 680 | 960 | 380 | 165 |
355G/ 400P-4 | 355 | 400 | 620 | 1700 | 580 | 407 |
400G/ 450P-4 | 400 | 450 | 620 | 1700 | 580 | 407 |
450G/ 500P-4 | 450 | 500 | 620 | 1700 | 580 | 407 |
500G-4 | 500 | – | 620 | 1700 | 580 | 407 |
Applications
Air Compressors
Winding Machines
Printing and Packaging Machines
Ceramic Equipment
Conveyor Systems
Environmental Protection Equipment
Food Processing Machinery
Woodworking Machines
Textile Machinery
Plastic Machinery
TÜV SÜD A.C.T. (ACCEPTANCE OF CLIENT TESTING)
ABOUT 3 Phase 400V VFDs with Advanced Features
The GD350A 400V VFD is a powerful and versatile frequency inverter designed specifically to meet the diverse needs of our customers.
It incorporates a dedicated TI motor control processor and comes standard with a multifunctional LCD keypad.
The GD350A 400V VFD seamlessly combines the control of asynchronous motors and permanent magnet synchronous motors, providing integrated speed, torque, and position control.
With its robust expandability and flexibility through PG card, PLC card, communication card, and IO card, it can be easily customized to meet individual customer requirements.
FAQ
How do I configure the closed-loop vector control of a Permanent Magnet Synchronous Motor (PMSM) on the GD350A 400V VFD?
The GD350 Frequency Inverter 400V offers comprehensive support for closed-loop vector control mode of permanent magnet synchronous motors. In this video, we will guide you through the configuration process using a servo motor with an incremental encoder.
How to connect the GD350A 400V VFD via WLAN?
Connect your GD350 400V VFD via WLAN to enable remote control and monitoring functions via a PC or mobile app. By utilizing WLAN connectivity, you can enhance the intelligence and efficiency of your device. Watch this step-by-step video guide.
How to connect the GD350A 400V VFD to Siemens S7-1200 PLC via the Profinet expansion card
This step-by-step tutorial will walk you through the process of establishing a seamless connection between the GD350A 400V VFD and the Siemens S7-1200 PLC to create an efficient and synchronized operating environment. Watch the video below for detailed instructions.
Need more information?
GD350A Catalog
Energy Efficiency Certification
Technical Data Sheet
GD350A User Manual
Login to download more information