Overview of R32 EVI DC Inverter Heat Pump

  • Experience high exchange efficiency and high outlet water with Poolworld’s R32 EVI DC Inverter Heat Pump, thanks to its full DC inverter and EVI technology.
  • This technology enables the unit to stably run in extremely cold areas of up to -30°C and provide hot water with a maximum outlet temperature of 60°C.”
  • Designed specifically for various types of European private houses, hotels, and apartments, the R32 EVI DC Inverter Heat Pump is the ideal solution for reliable and efficient heating.

MULTI-FUNCTIONAL HEAT PUMP: 5 WORKING MODES

  1. Space heating
  2. Space cooling
  3. Domestic hot water (DHW)
  4. Heating and DHW (with priority given to DHW)
  5. Cooling and DHW (with priority given to DHW)

OPERATING MODES OVERVIEW

Key Features

  • Provides heating, cooling, and hot water all year round
  • High Seasonal Coefficient of Performance (SCOP) of 4.65
  • High Heat Exchanger Efficiency with R32 Refrigerant
  • Energy Efficiency Class A+++
  • Delivers hot water up to 60℃
  • Extreme low temperature operation down to -30℃
  • Low Noise Operation
  • Intelligent Defrosting
  • System 4-inch LCD Touchscreen Controller
  • Built-in Wi-Fi Module for Remote Control
  • Intelligent Temperature Control with ±0.1°C Accuracy
  • Supports RS485 and Modbus Protocols
  • Supports IoT Remote Control
  • Supports SG and EVU Functions

EFFICIENCY AND PERFORMANCE VERIFIED BY TÜV

 

    Energy Label A+++

     SCOP up to 4.65

    Intelligent defrosting

    Two electric heater control ports

SMART GRID READY AND EVU COMPLIANT HEAT PUMP

  • The R32 EVI DC Inverter Series heat pump is equipped with advanced SMART GRID READY (SG-READY) and EVU functionalities that allow it to connect to the smart grid and be controlled by it.
  • By responding to the EVU photovoltaic signal and the peak period of local electricity consumption, the heat pump can intelligently adjust its operation mode, maximizing the use of solar energy storage power and minimizing energy consumption costs for users.
  • With its SG-READY and EVU capabilities, the R32 EVI DC Inverter Series heat pump enables sustainable and efficient energy use, helping to reduce carbon footprint and support a greener environment.

REMOTE CONTROL AND MONITORING

  • The R32 EVI DC Inverter Series heat pump is equipped with a built-in Wi-Fi module, which allows users to control and monitor the unit through the “Smart Life” App.
  • With the App, users can easily set timers, adjust temperature, switch between modes, and select language.
  • Users can remotely monitor the unit’s operating parameters, including temperature, energy consumption, and error codes, providing them with real-time information and control over their heat pump.
  • The remote control and monitoring function enables users to conveniently and efficiently manage their heat pump, optimizing its performance and reducing energy costs.

IOT MANAGEMENT PLATFORM FOR EFFICIENT CUSTOMER SERVICE

POOLWORLD’s IoT management platform helps dealers save on labor costs by enabling remote monitoring of data and recording all operating parameters of the heat pumps. The platform can be connected via WIFI or DUT and the recorded data can be synchronized with the management console of both dealers and manufacturers. In case of an error report, the dealer can quickly provide users with the best possible solutions based on the report. This efficient customer service helps ensure a smooth and hassle-free experience for the users.

Business Management
  • Project Management
  • Device  Management
  • Fault Management
  • User Management
  • Authority Management
  • Product Management
  • Institution Management
  • Distributor Management
Real-time Monitoring
  • Project Monitoring
  • View Device List
  • Monitoring Page
Data Statistics & Analysis
  • Project Statistics
  • Device Statistics
  • Fault Statistics
  • Project Monitoring
  • View Data Statistics
After-sales Management
  • Customer Complaint
  • Customer Maintenance
  • Order Management

Product design

Monoblock Type

The R32 EVI DC Inverter Monoblock Heat Pump features full DC inverter technology, which provides a more consistent and comfortable room temperature while increasing energy efficiency by 50%-70%. This technology allows the heat pump to adjust its output to match the heating or cooling requirements of the space, ensuring that the temperature remains stable and comfortable. Additionally, the full DC inverter technology reduces energy consumption and lowers operating costs.

Split Type

OUTDOOR UNIT

INDOOR UNIT

SPECIFICATION

MONOBLOCK TYPE

ModelPD30-CRL-DCPD40-CRL-DCPD50-CRL-DCPD60-CRL-DCPD80-CRL-DCPD100-CRL-DC
HeatingHeating Capacity Range(kw)1.57~8.404.40~13.005.9~18.27.5~23.010.2~28.012.8~35.0
Heating Input Range(kw)0.32~1.870.90~3.021.20~4.111.53~5.232.07~6.362.61~7.99
Current Range(A)1.42~8.301.39~4.68/ 4.12~13.81.86~6.37/ 5.49~18.82.37~8.113.70~11.44.67~14.3
Cop Range4.49~4.914.30~4.904.43~4.924.40~4.904.40~4.924.38~4.90
CoolingCooling Capacity Range (kW)0.99~6.222.80~8.203.81~11.534.73~14.66.54~19.88.13~24.6
Cooling Input Power(kw)0.29~2.180.85~3.311.11~4.051.39~5.141.92~6.972.42~8.75
Current Range(A)1.28~9.671.32~5.13/ 3.89~15.11.72~6.28/ 5.08~18.52.16~7.973.43~12.54.33~15.6
EER Range2.85~3.412.48~3.292.85~3.432.84~3.402.84~3.402.81~3.36
DHWHeating Capacity Range(kw)1.28~6.813.52~10.504.80~14.726.1~18.512.3~20.413.6~22.6
Heating Input Range(kw)0.31~2.130.88~3.391.17~4.601.53~5.972.8~5.373.09~5.95
Current Range(A)1.38~9.451.36~5.26/ 4.03~15.51.82~7.15/ 5.35~21.12.37~9.265.0~9.65.52~10.6
Cop Range3.2~4.13.1~4.03.2~4.13.1~4.03.8~4.43.8~4.4
Power Supply230V/1Ph/50-60Hz380V-400V/3Ph/50-60Hz or 220V-230V/1Ph/50-60Hz380V-400V/3Ph/50-60Hz
RefrigerantR32
Working Ambient Temperature-30~43°C
Water Circulation(m³/h)1.42.23.144.86
Water Pressure Drop(kpa)312535454050
IP ClassIPX4IPX4IPX4IPX4IPX4IPX4
Anti-electric Shock RateIIIIII
Noise at 1m (dB(A))≤53≤55≤57≤58≤62≤66
Net Weight/gross Weight(KG)110/120140/150170/180180/190210/220230/240
Diameter Of Pipe (mm)DN25DN25DN25DN25DN32DN32
Body Size(W*D*H) (mm)970X475X8351100X475X9851050X480X13301050X480X13301160X500X15801160X500X1580
Loading Quantity (20GP/40GP/40HQ)44/88/8844/88/8822/42/4222/42/4218/40/4018/40/40
Erp Level (35°c)A+++A+++A+++A+++A+++A+++
Erp Level (55°c)A++A++A++A++A++A++
Power SupplyPlate Heat Exchanger
Fan MotorDC Type
DefrostingBy Four-way valve
Operating Water Temperature (°c) DHW9~60°c
Operating Water Temperature (°c) Heating9~50°c
Operating Water Temperature (°c) Cooling7~35°c

SPLIT TYPE

DC INVERTER HEAT PUMP FOR HEATING COOLING AND DHW(R32)
OUTDOOR UNIT
PRODUCT MODELPD30-CRL-DCF-T/SPD40-CRL-DCF-T/SPD50-CRL-DCF-T/SPD40-CRL-DCF-TPD50-CRL-DCF-TPD60-CRL-DCF-T
HeatingHeating Capacity Range (kW)4.2~8.06.5~12.68.6~18.06.5~12.68.6~18.010.5~22
Heating input Range (kW)0.91~1.891.41~2.991.85~4.241.41~2.991.85~4.242.27~5.2
COP Range4.23~4.644.21~4.624.25~4.654.21~4.624.25~4.654.23~4.63
CoolingCooling capacity Range (kW)2.9~5.84.2~8.26.2~12.34.2~8.26.2~12.37.2~14.2
Cooling input power(kW)0.89~2.331.30~3.331.86~4.801.30~3.331.86~4.802.17~5.55
EER Range2.49~3.272.46~3.232.56~3.332.46~3.232.56~3.332.56~3.32
DHWHeating Capacity Range (kW)3.6~6.85.5~10.57.3~14.65.5~10.57.3~14.68.8~17.5
Heating input Range (kW)0.93~2.191.42~3.421.85~4.661.42~3.421.85~4.662.24~5.61
COP Range3.10~3.893.07~3.863.13~3.953.07~3.863.13~3.953.12~3.93
Heated water output (L/H)146225313225313375
RefrigerantR32
Power supply230V/1Ph/50-60Hz380V/3Ph/50-60Hz380V/3Ph/50-60Hz380V/3Ph/50-60Hz
Working area(°C)-30~43
IP Grade (Level of protection)IPX4
Anti-electric shock RateI
Noise (dB(A))≤53≤55≤57≤55≤57≤58
Net weight(kg)859513595135140
Body size(W*D*H) (mm)970×475×8201030×475×9701000×480×13801030×475×9701000×480×13801000×480×1380
ErP Level (35°C)A+++A+++A+++A+++A+++A+++
ErP Level (55°C)A++A++A++A++A++A++
Compressor BrandPanasonic
Four-way valveSanhua
Expansion valveSanhua
Operating water temperature (°C) DHW20~55
Operating water temperature (°C) heating20~55
Operating water temperature (°C) cooling7~35
Remark:Heating working condition: Inlet water temperature 30°C, Outlet water temperature 35°C, Dry bulb temperature 7°C, Wet bulb temperature6°C.
Cooling working condition:Inlet water temperature 12°C, Outlet water temperature 7°C, Dry bulb temperature 35°C, Wet bulb temperature 24°C.
DHW working condition: Inlet water temperature 15°C, Outlet water temperature 55°C, Dry bulb temperature 7°C, Wet bulb temperature 6°C.
DC INVERTER HEAT PUMP FOR HEATING COOLING AND DHW(R32)
INDOOR UNIT
Product modelPD40-CRL-DCF-TPD60-CRL-DCF-TPD40-CRL-DCF-TPD60-CRL-DCF-T
Power supply230V/1Ph/50-60Hz
Water pump typeSHIMGE / Adjustable DC inverter
Max water head(m)912912
Auxiliary electric heater(kW)3333
Expansion vessel(L)2585
Safety valve(MPa)0.30.30.30.3
3-Way ValveDN25
2-Way ValveDN25//
Diameter of pipe (mm)DN25
Water pressure drop (kPa)25352535
Body size(W*D*H) (mm)700×520×272740×520×312
Net weight(kg)35403842
PD30-CRL-DCF-T/SPD50-CRL-DCF-T/SPD30-CRL-DCF-T/SPD50-CRL-DCF-T/S
Applicable ModelsPD40-CRL-DCF-T/SPD50-CRL-DCF-TPD40-CRL-DCF-T/SPD50-CRL-DCF-T
PD40-CRL-DCF-TPD60-CRL-DCF-TPD40-CRL-DCF-TPD60-CRL-DCF-T

 